Zeile 10: Zeile 10:
||'''Month'''||'''Graph'''||'''Data file'''||'''Accuracy'''||'''Precision'''||'''Remarks'''||
||May 2014|| || || || || ||
||Apr 2014|| || || || || ||
||Mar 2014|| || || || || ||
||Feb 2014|| || || || || ||
||<#8080FF> '''Month'''||<#8080FF> '''Graph'''||<#8080FF> '''Data file'''||<#8080FF> '''Accuracy~-^1^-~'''||<#8080FF> '''Precision~-^2^-~'''||<#8080FF> '''Remarks'''||
||<#E0E0FF> May 2014||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF>~- CO,,2,,: 0.6 ppm <<BR>> CH,,4,,: 0.003 ppm -~||<#E0E0FF> ||
||<#E0E0FF> Apr 2014||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF>~- CO,,2,,: 0.6 ppm <<BR>> CH,,4,,: 0.003 ppm -~||<#E0E0FF> ||
||<#E0E0FF> Mar 2014||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF>~- CO,,2,,: 0.5 ppm <<BR>> CH,,4,,: 0.003 ppm -~||<#E0E0FF> ||
||<#E0E0FF> Feb 2014||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF> ||<#E0E0FF>~- CO,,2,,: 0.6 ppm <<BR>> CH,,4,,: 0.004 ppm -~||<#E0E0FF> ||
~- The FGGA is compared to a CO,,2,, standard gas approximately every two weeks. -~ <<BR>>
~- ^1^Accuracy is given in terms of the uncertainty the CO,,2,, standard gas and the deviation between FGGA and the standard. -~ <<BR>>
~- ^2^Instrument presision is determined as the standard deviation determined during the standard measurements. -~ <<BR>>

The full specifications of the Fast Greenhouse Gas Analyzer are found [[http://www.lgrinc.com/analyzers/overview.php?prodid=23&type=gas|here]].

Trace gas observations with Los Gatos ICOS Analyzers on the FZJ meteorological tower

100 m Platform, Fast Greenhouse Gas Analyzer, CO2, CH4, H2O

Near real time data of the past 24 hours can be viewed here.

Past data starting from February 2014 can be downloaded from the table below. Data are grouped in monthly files of 10-minute averages.
If you would like to get older data or data with higher time resolution, please contact Marc von Hobe.

Month

Graph

Data file

Accuracy1

Precision2

Remarks

May 2014

CO2: 0.6 ppm
CH4: 0.003 ppm

Apr 2014

CO2: 0.6 ppm
CH4: 0.003 ppm

Mar 2014

CO2: 0.5 ppm
CH4: 0.003 ppm

Feb 2014

CO2: 0.6 ppm
CH4: 0.004 ppm

The FGGA is compared to a CO2 standard gas approximately every two weeks.
1Accuracy is given in terms of the uncertainty the CO2 standard gas and the deviation between FGGA and the standard.
2Instrument presision is determined as the standard deviation determined during the standard measurements.

The full specifications of the Fast Greenhouse Gas Analyzer are found here.